Checkpoints
- High performance patented sugar polarimeter
- Intuitive user interface
- No re-calibration needed
- High stability of measuring values
- Measurement of dark samples after filtration with SCHMIDT + HAENSCH Autofilt Zwith NIR-WL
- High resolution 7″ TFT touchscreen
- Energy saving LED light source
- Combination with Polarimetry possible – SCHMIDT + HAENSCH Purity Analyzer
Easy to use
With the use of corresponding polarimeter tube and its self-sealing coupling for quick and safe connection to water circulators, an automatic temperature compensation is made possible. The Polartronic V allows even for dark samples with a high absorption to be measured at NIR wavelength (882.6 nm) after filtration with the AutoFilt Z unit. Additional clarification is not necessary. Paired with ATR P, Pol and Brix values can be measured simultaneously – see SCHMIDT + HAENSCH Purity Analyzer. The continuous measurement can be performed under user-specific methods selected over the intuitive operation system displayed by a high resolution 7” TFT touch screen that can be individually adapted. In addition to the freely programmable formulas up to 1000 scales are freely programmable.
Applications
The Saccharomat V is most often used within the sugar industry and sugar harvest, making it relevant for agriculture. Sugar purity and dark molasses can be analyzed with the highest reliability.
Product in detail
As quartz has an optical rotatory dispersion (ORD) almost identical to that of a sucrose solution, SCHMIDT + HAENSCH developed a unique mechanism using a quartz wedge to compensate for small wavelength shifts. In other words, quartz and the sample react in an identical way to small shifts of wavelength, and these shifts are automatically compensated and the effect becomes irrelevant. This ensures long time stable high precision measuring results without the necessity of recalibration over the lifetime of the instrument. Beside the unnecessary recalibration the Saccharomat V uses an energy saving LED, keeping the maintenance efforts minimal. The functionality of the device can be monitored using triple quartz control plates.
Specifications
Measurement scales | °Z International Sugar Scale |
Measuring ranges | – 35°Z to + 105°Z |
Resolution | 0.01 °Z |
Precision | ± 0.01 °Z |
Reproducibility | ± 0.01 °Z |
Sensitivity | Up to OD 5 |
Wavelength | 1 or 2 wavelengths fixed: 587, 882 nm |
Response time | ≤ 4 sec. over the entire measuring range |
Measuring tubes | Different Models, 50, 100 or 200 mm length, Material: glass, stainless steel, acid-proof stainless steel, stainless steel tubes with integrated temperature sensor*** |
Temperature measurement | NTC sensor for measurement of sample temperature |
Range | 0 °C – 99 °C |
Resolution | 0.01 °C |
Precision | ± 0.1 °C |
Light source | LED, interference filter |
Display | 7″ TFT Touchscreen, 800 x 480 Pixel, 16 Bit colors |
Operation | Touchscreen, keyboard**, mouse**, barcode reader**, remote via PC** |
Interface / Communication | RS232 (1x), USB A (4x), USB B (1x), Ethernet (1x), W-LAN/LAN** |
Conformity | International Pharmacopoea, OIML, ASTM, ICUMSA, Australian Standard K157 |
Configuration
Top of Form
Accuracy Class | Choose an optionAccuracy: ±0.02°Z Resolution: ±0.01°Z Reproducibility: ±0.01°Z |
Wavelength Count | Choose an optionOneTwo |
Industry Configuration | Choose an optionRegularSugarPharmaCustomized |
Temperature Control | Choose an optionCompensated (none)Tempered tube (T-Cell)Customized |
Accessories
Flow-through tube thermostatable | Flow-through tube | Aquisys Software |
Glass tube with bubble trap | Flow-through tube with integrated temperature sensor | T-CELL |
Quartz control plates |